Skip to main content

Package Relevance Protocol


The following protocol details the package relevance scoring system.

[Relevance] % = [Total Points]/[Maximum Possible Points]

Facet must be selected to count towards relevance.

Packages of equal relevance are randomly ordered for each new search in a way that avoids prioritizing any specific seller.

Relevance Color Codes:
Full Match (100%)
High Match (70% to <100%)
Partial Match (40% to <70%)
Low Match (>0% to <40%)
No Match (0%)
Facet Options Description Points
Zipcode Enter US zip code Matches packages with providers in the same state as zip code. 15
Installation and Assurance Toggle Required Packages including installation and assurance get full points 5
Customer Engagement Network-Eligible Packaged Systems Toggle Required Customer Engagement Network-Eligible Packaged Systems get full points 2
Size (kW) Enter target size (kW) and allowed range (%) Matches packages with size within range (entered size ±range%). Full 10 points at target size decreasing to 6 points on the edge of the range.
Package greater than 150% of size
Package less than 25% 0f size
6-10
-10
Prime Movers Select one or more:
  • Reciprocating engines
  • Combustion turbines
  • Microturbine
  • Fuel Cell
  • Back Pressure Steam Turbine
  • Organic Rankine Cycle

Packages that exactly match 1 of the selected get full points

5

Fuel Types Select one or more:
  • Natural Gas
  • Propane
  • Digester Gas
  • Landfill Gas
  • 100% Hydrogen
  • Low Temperature Heat

Packages that exactly match 1 of the selected get full points


Packages that do not match any of the selected

15


-10
Hydrogen Blend Capable Toggle Required

Packages with optional Hydrogen Blend Capable get full points

5

Thermal Outputs Select one or more:
  • Hot Water
  • Chilled Water
  • Steam
  • Direct Process Heat/Drying
  • ORC

Packages that exactly match 1 of the selected get full points


Packages that only match some of the selected outputs get proportionately adjusted points based on matches versus total selected outputs.

Packages that have unselected outputs get proportionately adjusted points based on matches versus total outputs.

10

Grid Connection Type Select one or more:
  • Grid Parallel Only
  • Grid Island, Black Start, Manual Transfer
  • Grid Island, Black Start, Auto Transfer

Packages that exactly match 1 of the selected get full points

5

Packaged in America Toggle Required Packaged in America Systems get full points 2
Outdoor Installation Toggle Required Packages with Standard Outdoor Installation receive full points
Packages with Optional Outdoor Installation receive half points
10
Packaged System Footprint Set one or more:
  • Width
  • Length
  • Height

Packages that are within the selected footprint get full points.

Height is only compared with height.

If only length or width is selected, it is only compared against the shorter package length and width dimensions, unless ">50" is selected, which is compared against the longest length or width package dimension.

If both length and width are selected, The longest is compared to the longest package length or width dimension while the shorter of the 2 are compared.

2